Beam Reinforcement
Top bars, bottom bars and links for a set of identical beams, with link cutting lengths to BS 8666.
Step 1 · New to this? Start here
The basics
A beam carries the slab and walls above it and passes the load to the columns. Like a slab, it bends, so it needs steel at the bottom where it is pulled, and usually some bars at the top to hold the links and resist hogging over supports.
Links (stirrups) are the closed rectangles of steel that wrap around the main bars. They resist shear and hold the cage together. They are placed at a spacing along the beam, often closer near the supports.
The length of each link is found from BS 8666 shape code 51, which allows for the bends and the two hooks that close it. This is the same rule used in our Bar Bending Schedule calculator.
- b × h
- Beam width × overall depth, in mm. For example 230 × 450.
- 3Y16 bottom
- Three Y16 bars at the bottom of the beam.
- Y8 @ 200
- Y8 links at 200 mm centres.
- Shape 51
- The BS 8666 shape code for a closed rectangular link.
- Anchorage
- The extra length a bar runs into the support so it cannot pull out.
Step 2
How to use this calculator
- 1Count how many identical beams there are on the drawing and enter that number.
- 2Enter the beam length end to end, and the beam width and depth in mm.
- 3Enter the cover, then the number and size of bottom bars and top bars per beam.
- 4Enter the extra length per bar for bends or anchorage into the columns (check the detail on the drawing).
- 5Enter the link size and spacing, then read the link cutting length and the total steel weight.
Step 3 · Enter your numbers
Results
Estimates for learning and planning. Always confirm quantities with your engineer or quantity surveyor.
Step 4 · Check your understanding
Worked example
Four beams, each 5 m long and 230 × 450 mm, cover 25 mm, 3Y16 bottom, 2Y12 top, 300 mm extra per bar, Y8 links @ 200.
- 1. Main bar length = 5 − 0.05 + 0.30 = 5.25 m
- 2. Bottom bars = 4 × 3 × 5.25 × 1.580 = 99.56 kg
- 3. Top bars = 4 × 2 × 5.25 × 0.889 = 37.33 kg
- 4. Links per beam = (5,000 − 50) ÷ 200 = 24.75, rounded down to 24, + 1 = 25 links
- 5. Link size A = 230 − 50 = 180 mm, B = 450 − 50 = 400 mm
- 6. Link length = 2(180 + 400) + 2 × 80 − 1.5 × 16 − 3 × 8 = 1,272, rounded up to 1,275 mm
- 7. Links = 4 × 25 × 1.275 × 0.395 = 50.37 kg
Total steel for the four beams is about 187.26 kg, with 25 links per beam, each cut 1,275 mm long.
Common mistakes to avoid
- Using the clear span instead of the full beam length. Bars run into the supports, so measure end to end.
- Using one link spacing everywhere when the drawing shows closer links near the supports. Work out each zone separately.
- Forgetting the cover on both sides when sizing links. The link fits inside the cover, so A = b − 2 × cover.
How it's calculated
- Main bar length = beam length − 2 × cover + extra for bends or anchorage
- Links per beam = (beam length − 2 × cover) ÷ spacing, rounded down, + 1
- Link outside size A = b − 2 × cover, B = h − 2 × cover
- Link cutting length = 2(A + B) + 2C − 1.5r − 3d, where C = 10d (min 70 mm) and r = 2d, rounded up to 25 mm
- Weight = total length × d² ÷ 162