All calculators

Concrete Cube Test

Turn crushing loads from the lab into concrete strength and see how your cubes compare with the grade.

Step 1 · New to this? Start here

The basics

A cube test is how we prove the concrete on site is as strong as the drawing asks for. Fresh concrete is filled into steel moulds, usually 150 mm cubes, cured in water and then crushed in a machine at the lab.

The machine reads the load at which the cube fails, in kilonewtons (kN). Strength is that load spread over the face of the cube. A 150 mm cube has a face of 150 × 150 = 22,500 mm², so strength = load × 1,000 ÷ 22,500, in N/mm² (the same as MPa).

Cubes are normally made in sets of three and the average is used. Results at 7 days give an early warning. The 28-day result is the one used to judge whether the concrete meets the grade.

Failure load
The highest load the cube carried before crushing, in kN.
N/mm²
Newtons per square millimetre, the same as MPa.
Grade
The specified strength. In BS 8110 practice, C25 means a cube strength of 25 N/mm².
Curing
Keeping the cubes in water at a steady temperature until testing.

Step 2

How to use this calculator

  1. 1Pick the cube size used by the lab, usually 150 mm.
  2. 2Enter the failure load of each of the three cubes from the lab report, in kN.
  3. 3Enter the specified strength (the grade) from the drawing or specification.
  4. 4Choose the age of the cubes when crushed.
  5. 5Read each cube strength, the average, and how it compares with the grade.

Step 3 · Enter your numbers

Results

Average strength of the three cubes
23.2 N/mm²
Cube 1
23.1 N/mm²
Cube 2
24.0 N/mm²
Cube 3
22.4 N/mm²
Average as a percentage of the grade
93 %
Rough guide for 7-day cubes (about 65% of grade)
16.3 N/mm²

Estimates for learning and planning. Always confirm quantities with your engineer or quantity surveyor.

Step 4 · Check your understanding

Worked example

Three 150 mm cubes crushed at 7 days failed at 520, 540 and 505 kN. The specified grade is C25.

  1. 1. Cube 1 = 520 × 1,000 ÷ 22,500 = 23.1 N/mm²
  2. 2. Cube 2 = 540 × 1,000 ÷ 22,500 = 24.0 N/mm²
  3. 3. Cube 3 = 505 × 1,000 ÷ 22,500 = 22.4 N/mm²
  4. 4. Average = (23.1 + 24.0 + 22.4) ÷ 3 = 23.2 N/mm², which is 93% of 25
  5. 5. A rough 7-day guide is about 65% of 25 = 16.3 N/mm², so these cubes are well on track

The 7-day average is 23.2 N/mm². That is a good early result for C25 concrete, so wait for the 28-day cubes to confirm.

Common mistakes to avoid

  • Using the 7-day result to accept or reject concrete. Acceptance is based on 28-day results and the rules in the specification.
  • Forgetting to convert kN to N. Multiply the load by 1,000 before dividing by the area in mm².
  • Poor cube making. Badly compacted or uncured cubes give low results even when the concrete in the structure is fine.
How it's calculated
  • Strength (N/mm²) = failure load (kN) × 1,000 ÷ loaded area (mm²)
  • Loaded area of a 150 mm cube = 150 × 150 = 22,500 mm²
  • Average = sum of the three cubes ÷ 3
  • Early-age guide (ordinary Portland cement, typical): 3 days about 40%, 7 days about 65%, 14 days about 90%, 28 days about 99% of the 28-day strength. Cement type and curing change this a lot
  • Compliance is judged on 28-day results using the rules in your specification (for example BS EN 206), not on this rough guide