Formwork Area
How much formwork a slab, beam, column or wall needs, and how many plywood sheets to buy.
Step 1 · New to this? Start here
The basics
Formwork is the temporary mould that holds wet concrete until it hardens. It is usually priced and planned by contact area, the surface of formwork that actually touches the concrete, in m².
Each element has its own rule. A slab needs its underside (soffit) plus the edge boards. A beam needs two sides and a bottom. A column needs all four sides, and a wall needs both faces.
Plywood sheets measure 8 × 4 ft (2.44 × 1.22 m), which is about 2.98 m² each. If you strip carefully you can reuse sheets several times, so you buy fewer.
- Contact area
- The formwork surface in contact with the concrete.
- Soffit
- The underside of a slab or beam.
- Striking
- Removing the formwork once the concrete is strong enough.
- Reuse
- How many pours each sheet will serve.
Step 2
How to use this calculator
- 1Pick the element: slab, beam, column or wall.
- 2Enter how many identical elements there are.
- 3Enter the sizes in metres. For beams, use the depth below the slab, because the slab formwork already covers the top.
- 4Enter how many times each sheet will be used and a wastage figure for cutting.
- 5Read the contact area and the number of plywood sheets to buy.
Step 3 · Enter your numbers
Results
Estimates for learning and planning. Always confirm quantities with your engineer or quantity surveyor.
Step 4 · Check your understanding
Worked example
One slab 5 m × 4 m, 150 mm thick, plywood used once, 10% wastage.
- 1. Soffit = 5 × 4 = 20.0 m²
- 2. Edges = 2 × (5 + 4) × 0.15 = 2.7 m²
- 3. Contact area = 20.0 + 2.7 = 22.7 m²
- 4. Sheets = 22.7 × 1.10 ÷ 2.977 = 8.4, rounded up to 9 sheets
The slab needs 22.7 m² of formwork, about 9 plywood sheets of 8 × 4 ft.
Common mistakes to avoid
- Counting the top of a beam. Where the slab is cast with the beam, the slab formwork already covers it.
- Forgetting props, ledgers and timber bearers. This calculator covers the sheeting only.
- Assuming many reuses with poor stripping and storage. Damaged sheets cannot be reused.
How it's calculated
- Slab = length × width + perimeter × depth (edge forms)
- Beam = (2 × depth below the slab + width) × length
- Column = 2 × (width + depth) × height
- Wall = 2 × length × height
- Sheets = area × (1 + wastage) ÷ 2.977 m² ÷ number of reuses, rounded up